Electrophoretic light refining unit (I / R)
1. The resin of British brand is used to ensure that the impurity ion in the electrophoresis tank does not exceed the standard.
2. The technological process is designed by foreign advanced technology, easy to operate and practical.
Parameters of electrophoresis light refining unit
1) Design conditions and calculation
a) Liquid volume: 24m3 / h
b) Liquid condition: temperature: 25 ℃. Viscosity: 2cp supply pressure: 3kg / C ㎡
c) Resin quantity:
Anion exchange resin: 1000 l
Cation exchange resin: 350 L
d) Design pressure: resin tower: 3 kg / C ㎡
2) Equipment content and performance parameters:
a) Device type: manual ir-ed-350 / 1000
b) Cation exchange resin tower: resin quantity: 350 L (bleach)
Size: Φ 1150x1700 (H) material: steel plate lined with hard rubber
c) Anion exchange resin tower: resin quantity: 1000 l (bleach)
Size: Φ 1200x2000 (H) material: steel plate lined with hard rubber
d) Hydrochloric acid metering tank: capacity: 100 L
Size: Φ 500x600 (H) material: steel plate lined with hard rubber
e) Caustic soda metering tank: capacity: 500 L
Size: Φ 800x1000 (H) material: SUS304
f) Ammonia metering tank: capacity: 100L
Size: Φ 500x600 (H) material: PVC
g) Purge tank:
Size: Φ 200x500 (H) material: PVC
h) Ejector class
Material: SS41 + polytetrafluoroethylene
Material: SUS304
I) instrument:
Pressure gauge 0-5kg / C ㎡
Flowmeter: Rotameter
j) The base plate and bracket are made of 304 stainless steel
k) Approximate size: 2500x6000x2500